Grain-oriented electrical steel · A Standard Company

The steel insideevery transformer

A silicon-iron alloy with the metal's crystals aligned to slash core loss. Rolled as thin as nine-thousandths of an inch, melted and finished entirely in the United States.

6%silicon contentHIGH-SI ALLOY
0.009inminimum gaugeCOLD-ROLLED
0.85 W/kgcore loss at 1.7TGRAIN-ORIENTED
100%domestic meltMADE IN USA
6%silicon contentHIGH-SI ALLOY
0.009inminimum gaugeCOLD-ROLLED
0.85 W/kgcore loss at 1.7TGRAIN-ORIENTED
100%domestic meltMADE IN USA
The material

Engineered at the
grain level.

01

Oriented Grain Structure

The alloy's crystals are aligned along the rolling direction, so magnetic flux travels the easy axis. The result is dramatically lower hysteresis loss inside the core.

02

High-Silicon Chemistry

Silicon raises electrical resistivity and suppresses eddy currents. We push content up to 6% — far beyond conventional grades — for the highest core conductivity.

03

Nine-Thousandths Gauge

Rolled into sheets as thin as 0.009 inches and stacked by hand into laminations. Thinner laminations mean fewer eddy currents and a cooler, quieter transformer.

04

Low Core Loss

Domain-refined and tension-coated to reach core loss below 0.9 W/kg at 1.7T. Every coil is Epstein-tested and certified before it leaves the mill.

AB
The process

From molten iron
to finished coil.

process.spec
1STAGE      melt + refine
2furnace    electric-arc (EAF)
3silicon    up to 6.0% Si
4carbon     < 0.003% C
5refine     vacuum decarburization
6status     chemistry locked
Line running
Domestic supply

One of the only
mills in the U.S.

Grain-oriented electrical steel is a strategic material — and almost none of it is made domestically. We melt, roll, anneal, and coat a full range of grades on U.S. soil, insulating the grid from fragile overseas supply chains.

100%
Domestic melt
6
Standard grades
6%
Peak silicon
Grade / Gauge · core loss @ 1.7T, 50HzIn production
M-2 / 0.18mm
Domain-refined, HGO
0.68 W/kg
M-3 / 0.23mm
High-permeability GOES
0.85 W/kg
M-4 / 0.27mm
High-permeability GOES
0.97 W/kg
M-5 / 0.30mm
Conventional GOES
1.11 W/kg
M-6 / 0.35mm
Conventional GOES
1.31 W/kg
6% Si / 0.10mm
High-silicon, motor grade
N/A
By the numbers

Measured in
watts and microns.

Mill floor|5:38:51 AM
0 t
Annual coil capacity
0.8%
Stacking factor
−0%
Lower core loss vs. legacy grades
0+
Laminations shipped
Applications

Wherever energy
changes form.

From grid-scale power transformers to EV traction motors — anywhere a magnetic core has to move flux without wasting it.

Power Transformers
Grid-scale cores
Distribution Transformers
Pole & pad-mount
Grid Reactors
Reactive compensation
Instrument Transformers
Metering & protection
EV Traction Motors
High-silicon laminations
Industrial Motors
Rotor & stator stacks
Generators
Utility & standby
Wind Turbine Converters
Renewable interconnect
Rectifier Transformers
Industrial DC
Data-Center UPS
Isolation transformers
Rail Traction
Onboard transformers
HVDC Converters
Long-haul transmission
Power Transformers
Grid-scale cores
Distribution Transformers
Pole & pad-mount
Grid Reactors
Reactive compensation
Instrument Transformers
Metering & protection
EV Traction Motors
High-silicon laminations
Industrial Motors
Rotor & stator stacks
Generators
Utility & standby
Wind Turbine Converters
Renewable interconnect
Rectifier Transformers
Industrial DC
Data-Center UPS
Isolation transformers
Rail Traction
Onboard transformers
HVDC Converters
Long-haul transmission
HVDC Converters
Long-haul transmission
Rail Traction
Onboard transformers
Data-Center UPS
Isolation transformers
Rectifier Transformers
Industrial DC
Wind Turbine Converters
Renewable interconnect
Generators
Utility & standby
Industrial Motors
Rotor & stator stacks
EV Traction Motors
High-silicon laminations
Instrument Transformers
Metering & protection
Grid Reactors
Reactive compensation
Distribution Transformers
Pole & pad-mount
Power Transformers
Grid-scale cores
HVDC Converters
Long-haul transmission
Rail Traction
Onboard transformers
Data-Center UPS
Isolation transformers
Rectifier Transformers
Industrial DC
Wind Turbine Converters
Renewable interconnect
Generators
Utility & standby
Industrial Motors
Rotor & stator stacks
EV Traction Motors
High-silicon laminations
Instrument Transformers
Metering & protection
Grid Reactors
Reactive compensation
Distribution Transformers
Pole & pad-mount
Power Transformers
Grid-scale cores
Quality

Certified to
the coil.

Transformer cores run for decades — the steel inside them can't vary. Every heat is refined to spec, every coil is tested, and every shipment is fully traceable.

ASTM A876IEC 60404ISO 9001Buy AmericaRoHS

ASTM A876 certified

Every grade is tested and certified to the ASTM A876 standard for grain-oriented electrical steel.

Epstein-tested coils

Core loss and permeability verified on the Epstein frame — a mill certificate ships with every coil.

Full traceability

Heat-to-coil chemistry, gauge, and magnetic data are logged and retained for the life of the material.

Domestic & compliant

100% U.S. melt-and-pour, eligible for Buy America and federal grid-infrastructure procurement.

For engineers

Spec it in.
Ship it out.

Full datasheets, magnetic curves, and tolerances up front — plus finishing done to your drawing so it drops straight into your core build.

Custom slitting

Coils slit to your exact core width, ready to stack.

Cut laminations

Step-lap and mitered cuts to your CAD, delivered kitted.

Domain refining

Laser-scribed grades for the lowest achievable loss.

Just-in-time coils

Scheduled releases matched to your build cadence.

GRADE          Standard M-3 GOES
iron    (Fe)   balance
silicon (Si)   3.1 - 6.0%
carbon  (C)    < 0.003%
manganese(Mn)  < 0.10%
sulfur  (S)    < 0.006%
coating        MgO + phosphate
Products

Three families.
Every core.

Pick a grade family, then dial in gauge and finishing. Every order is quoted on your volume, geometry, and delivery schedule.

0.23 mm0.27 mmCore loss @ 1.7T, 50Hz
01 · M-5 / M-6

Conventional GOES

General-purpose distribution and small power transformers

1.11 W/kg
Typical core loss
  • 0.30 - 0.35 mm gauge
  • Standard grain orientation
  • Phosphate insulating coat
  • Coil or sheet form
  • ASTM A876 certified
Most Specified
02 · M-2 / M-3 / M-4

High-Permeability

Grid-scale power transformers and reactors

0.85 W/kg
Typical core loss
  • 0.18 - 0.27 mm gauge
  • High-permeability texture
  • Tension-inducing coating
  • Laser domain refining
  • Epstein mill certificate
  • Custom slitting & cut laminations
  • Just-in-time coil release
03 · Up to 6% Si

High-Silicon

EV traction and high-frequency motor laminations

By spec
Typical core loss
  • Down to 0.10 mm gauge
  • Elevated silicon (to 6%)
  • Maximum resistivity
  • High-frequency optimized
  • Rotor / stator kitting
  • Development partnership
  • NDA-backed custom alloys
  • Dedicated capacity

All grades ship with a full mill certificate and heat-to-coil traceability. Compare full specifications

Secure your
domestic supply.

Building transformers, reactors, or motors? Talk to our metallurgists about grades, gauges, and lead times — and lock in a U.S. source for grain-oriented electrical steel.

MOQ applies · quotes within two business days